1. Receivers. Display Panels, Repeaters, Over Door Lights, Radio Mains Switches, Brackets.
  2. Call Points, Hand Units, Door Contacts etc.
  3. Infrared Triggers. Ir Fobs, Pendants
  4. Paging transmitters & Pagers
  5. Accessories, Pear Push Leads etc
  6. HTM 6000 Adaptors Leads
  7. Assistive Technology, Floor Mats, Bed Mats etc
  8. Batteries
  9. Misc, Clips, Keys, Magnetic Door Fobs etc
  10. Connectors
  11. Room Unit Spares.
  12. Paging Extras.
  13. Power Supplies.
Product Image Description
HTM 4000 Numeric Display 7 inch colour backlit screen,
Basic functionality of displaying numbers only.
Replacement item for Medicare LED Panels
Power requirements non-switched socket outlet 240v a.c
Dimensions W x D x H : 200 x 80 x 150mm (H 380 with aerial)
HTM 4000 Display – 7 inch colour backlit screen,
Option of numeric or alphanumeric display.
Optional functions, Location map, Sounder, User-editable information,
Call accept, Zoning, Function buttons,
Power requirements non-switched socket outlet 240v a.c
Dimensions W x D x H : 200 x 80 x 150mm (H 380 with aerial)
HTM 4100 Display – 15 inch colour backlit screen,
Option of numeric or alphanumeric display.
Optional functions, Location map, Sounder, User-editable information,
Call accept, Zoning, Function buttons, Call logging,
Note: Required if e – logging to be installed.
Power requirements non-switched socket outlet 240v a.c
Dimensions W x D x H : 3905 x 90 x 3300mm (H 480 with aerial)
HTM 4031 RTX (Repeater / Signal Booster)
– Used within the building normally on the 1st Floor
to build a radio foot print to the desired parameters of the system.
This then enables receivers and transmitters to be installed anywhere
within the parameters.
Power requirements non-switched socket outlet 240v a.c
Dimensions W x D x H : 180 x 125 x 40mm (H 290 with aerial)
HTM 6032 Over Door Light
– Can be programmed to a number of call points
and will light up Orange, Green, Flashing Yellow, Flashing Red and
Flashing Blue dependant on call type.
Optional sounder when activated.
Dimensions W x D x H : 85 x 36 x 85 plus back box depth.
HTM 4023 ODL Psu 12v 5 Amp
– Used to power up to 40 x HTM 6032 Over Door Lights.
Power requirements non-switched socket outlet 240v a.c
Dimensions vary.
HTM 4024 ODL Psu 12v 1 Amp
– Used to power up to 8 x HTM 6032 Over Door Lights
Power requirements non-switched socket outlet 240v a.c
Dimensions vary.
HTM 4025 ODL Psu 12v 3 Amp
– Used to power up to 25 x HTM 6032 Over Door Lights.
Power requirements non-switched socket outlet 240v a.c
Dimensions vary.
HTM 6033 Radio Mains SwitchRequires electrician to install.
Mains operated relay can be used for a number of applications
controlled by Medicare nurse call system.
1. Control en-suite light / reading light by activation of an
accessory type call for example activation of a Bed mat.
2. Control en-suite light / reading light by activation of light
switch on Htm 6018 two button lead.
HTM 6034 Radio Sounder
– Designed to be used within areas where audible alarm is needed but with no display.
When using audible sounders the practicalities of audibility but not
visual alarms need to be taken into consideration.
Volume control and battery backup is built into the design.
Power requirements non-switched socket outlet 240v a.c
Dimensions W x D x H : 180 x 125 x 40mm (H 290 with aerial)
MED 1 Flat Wall Bracket for 7” Panel
– Included with HTM 4000 display panel,
available as a replacement or spare.
Fixed to a flat surface using 3 screws.
Horse shoe cut out for easy Display panel removal.
Dimensions W x D x H : 200 x 80 x 6mm
MED 2 Flat Wall Bracket for 14” Panel
– Included with HTM 4100 display panel,
available as a replacement or spare.
Fixed to a flat surface using up to 7 screws.
Dimensions W x D x H : 126 x 17 x 126mm
MED 3 Swivel Bracket for 7” Panel
– Optional extra for use with a HTM 4000 Display Panel,
enables limited tilt of complete panel.
Brings the Panel a minimum of 95mm forward from the wall.
Dimensions W x D x H : 82 x 95 x 95mm
MED 2b Swivel Bracket for 14” Panel
– Optional extra for use with a HTM 4100 Display Panel,
enables limited tilt of complete panel.
Brings the Panel a minimum of 135mm forward from the wall.
Dimensions W x D x H : 115 x 133 x 115mm
MED4 USB to Serial Convertor
– For use with Paging transmitters to 14” Panels.
HTM 6000 Hand Unit
-The unit can be configured to operate in one or two-way mode.
All call points have an easy clean label which is simple to replace and
are designed specifically to withstand the rigours of even the toughest care facility.
Power requirements 2 x AA alkaline batteries.
Dimensions W x D x H : 70 x 30 x 190mm
HTM 6001 Pear Push Unit
– Supplied with Pear push lead as standard and wall bracket included.
The HTM 6001 is fitted with two sockets for connecting
accessories such as pressure mats, PIR triggers and much more.
This model has an automatic monitor function for situations such as bed occupancy monitoring.
Power requirements 2 x AA alkaline batteries.
Dimensions W x D x H : 70 x 30 x 190mm
HTM 6002 Neck / Belt Pendant
– Medicare pendant units are lightweight portable call devices that can be worn around the neck.
The soft fabric lanyard features a strain release clip for safety.
All call points have an easy clean label which is simple to replace
and are designed specifically to withstand the rigours of even the toughest care facility.
Programmable call type can activate on Call, Assistance or Emergency.
Power requirements 2 x AAA alkaline batteries.
Dimensions W x D x H : 47 x 29 x 102mm
HTM 6003 Pull Cord Unit
– Fitted with a pull cord.
The unit can be configured to operate in one or two-way mode.
All call points have an easy clean label which is simple to replace
and are designed specifically to withstand the rigours of even the toughest care facility.
Power requirements 2 x AA alkaline batteries.
Dimensions W x D x H : 70 x 30 x 190mm
HTM 6004 Door Unit / Contact
– The unit is easily armed and disarmed using a mag swipe fob,
activates when armed by door opening, featuring an
Emergency alarm button for added safety and security.
Universal fixing may be used for left or right handed doors,
Optional external mag-swipe for staff entry.
Programmable call type can activate on Call, Assistance or Emergency.
Power requirements 2 x AA alkaline batteries.
Dimensions W x D x H : 70 x 30 x 190mm
HTM 6004c Cardiac Alarm
– The unit is easily activated by pressing the cardiac button.
Designed to be used in a recovery area.
Alarms as a two tone fast cardiac call and shows blue on the display panels.
Power requirements 2 x AA alkaline batteries.
Battery life normal operating conditions up to 2 years.
Dimensions W x D x H : 70 x 30 x 190mm
HTM 6004b Door Contact Entry Mag Swipe
– For use with the HTM 6004 Door Contact.
Enables you to pass through a door without activating the alarm.
(Reed switch devices are slightly different.)
HTM 6004f Magnetic Fob
For use with the HTM 6004 Door Contact and Entry Mag Swipe.
HTM 6005 Ceiling Pull Cord
– Must be accompanied by either a HTM 6001 or
HTM 6003 to reset the call activated by the ceiling pull cord.
To be used when activation of an alarm is needed where
there are no walls within practical reaching distance.
To mount the unit for example by a bath in a semi assisted bathroom.
Power requirements 2 x AAA alkaline batteries.
Dimensions W x D x H : 85 x 85 x 50mm
HTM 6040 IR Fob
– An IR fob can be used with either the HTM 6001 or HTM 6003 unit.
This will enable to tag a Reset or staff Visit with a staff name or id number,
these are editable using the edit ident facility on the HTM 4100 (14” Display Panel.)
Each HTM 6040 IR Fob can be ordered with its own pre numbered id.
Power requirements 1 x 12v 23AE alkaline batteries.
Dimensions of Fob W x D x H : 36 x 17 x 66mm
HTM 6041 IR Neck / Belt Pendant
– Medicare IR pendant units are used with HTM 6001 &
HTM 6003 units when the Infra Red option is activated.
Enables the lightweight portable devices to activate the
transmitter by line of sight within 5 metres.
Programmable call type can activate on Call, Assistance or Emergency.
Power requirements 2 x AAA alkaline batteries.
Dimensions W x D x H : 47 x 29 x 102mm
MED 5 Paging Transmitter
– When using a paging transmitter a HTM 4000 or HTM 4100 is required
to interface with the nurse call system the paging transmitter.
Power requirements.
A double un-switched socket (not spur) is needed, this is normally geographically
in the middle of the building on the 1st floor.
This is where a paging transmitter and a panel can be installed.
(Note: If building is more than 3 storey building then the paging transmitter
will be installed geographically in the middle of the building next to a panel on the 2nd floor.)
Dimensions W x D x H : 140 x 45 x 185mm (H 450 with aerial and connections)
MED 6 Holstered Pager
– Receives call from the nurse call system via a paging transmitter Pagers
are used to alert staff whilst mobile around site.
Ideal to alert care staff whilst there with a resident or
in a room out of site to a display panel.
Power requirements 1 x AA alkaline battery.
Battery life with normal operating conditions 4 to 7 days.
Dimensions W x D x H : 77 x 20 x 54mm
MED 6R Holstered Rechargeable Pager
– Receives call from the nurse call system via a paging transmitter
Pagers are used to alert staff whilst mobile around site.
Ideal to alert care staff whilst there with a resident or
in a room out of site to a display panel.
Power requirements 1 x AA rechargeable battery.
Battery life with normal operating conditions last an 8 – 12 hr shift.
Dimensions W x D x H : 77 x 27 x 54mm
MED 6C Rechargeable Docking Station
– When pagers are not in use, they are inserted into the
docking station which recharges the battery for the next shift.
Power requirements non-switched socket outlet 240v a.c
Dimensions W x D x H : 115 x 120 x 88mm
HTM 6016 Bracket Wall Plate with Magnet
– Replacement Wall Plate for use with HTM 6001 hand unit
with either the HTM 6017 one button lead, or
HTM 6018 two button lead.
HTM 6017 Single Button Lead
– Used with HTM 6001 hand unit plugged into socket 2
when a straight lead is required. Generates an accessory call
when unplugged from the hand unit.
Has an easily replaceable clip for fixing to clothing or bed linen.
Held using a magnet to the HTM 6051 bracket / wall plate.
HTM 6018 Two Button Lead
– Used with HTM 6001 hand unit plugged into socket 2
when a straight lead is required.
Generates an accessory call when unplugged from the hand unit.
Has an easily replaceable clip for fixing to clothing or bed linen.
Held using a magnet to the HTM 6051 bracket / wall plate.
Additional feature of the HTM 6018,
when used with HTM 6033 Radio mains switch.
Additional control of reading light or En-suite light can be utilized.
HTM 6019 Round Button Pear Push Lead
– Available as a replacement part for use with HTM 6001 Hand units
used to activate a call when plugged into socket 2.
Reach’s up to 4 metres with retractable coil.
Label is Lexan with micro ban additive,
Luminescent properties for easy location in the dark,
guaranteed no fade, Can be cleaned safely with anti-bacterial cleaners,
compliant with FDA and USP requirements.
Available for HTM 6000 & HTM 4000 range.
HTM 6017 Kit Single Button Pear Push lead inc Mag wall plate
HTM 6018 Kit Two Button Pear Push lead inc Mag wall plate
HTM 6020 Adaptor Lead 30 cm
– 6p6c Accessory lead for connecting external triggers 30cm.
HTM 6021 Bed/Chair Mat Adaptor
Used with HTM 6001 in socket 1 to activate an Accessory call for
(automatic monitoring unit) for Med 9 & Med 10 Bed and Chair mats.
HTM 6022 Floor Mat adaptors
Used with HTM 6001 in socket 1 to activate an Accessory call
from a Med 7 & Med 8 Floor Mat or any Accessory from Medicare.
HTM 6023 Pull Monitor Jack & String (TABS) with HTM 6021
– When Red lead is pulled from the Accessory adaptor
an Accessory call type is activated.
HTM 6024 Door Bell Switch and Interface
For when the doorbell is required to activate the Nurse call system.
This can also be used as a push button entry for HTM 6004 Door Contacts.
HTM 6025 Blow Switch with Adaptor
MED 7. Standard Economy Floor Pressure Mat
– Plugs into socket 1 of a Medicare room unit via the relevant adaptor
either for use with an Htm6001 Pear push unit where an Accessory call
will activate by standing on the floor mat, or when using with an
HTM 4001 Pear push unit a normal call will activate by standing on the floor mat.
MED 8. Heavy Duty Floor Pressure Mat – Carpeted, nonslip mat.
– Plugs into socket 1 of a Medicare room unit via the relevant
adaptor either for use with an Htm6001 Pear push unit where an Accessory
call will activate by standing on the floor mat, or when using with an HTM 4001 Pear push
unit a normal call will activate by standing on the floor mat.
MED 9 Chair Pressure Mat
– Used with an HTM 6001 Pear push unit
plugged into socket 1 to activate an Accessory call for Med 9 Chair Mat.
The HTM 6001 Pear push unit automatically monitors pressure applied to the mat.
Then activates an Accessory call when released.
For example: A Person sitting down applying pressure.
Then when a Person gets up or off the Pressure Mat an Accessory call is activated.
MED 10 Bed Pressure Mat
Used with an HTM 6001 Pear push unit
plugged into socket 1 to activate an Accessory call for Med 10 Bed Mat.
The HTM 6001 Pear push unit automatically monitors pressure applied to the mat.
Then activates an Accessory call when released.
For example: A Person lying down applying pressure.
Then when a Person gets up or off the Pressure Mat an Accessory call is activated.
MED 11. Epilepsy Detection Unit
The Epilepsy monitors are the most advanced monitor and can be
applied to the most demanding situations.
It can monitor bed movement, Sound, Incontinence, Vomiting, and bed Vacation.
In this case the movement detection has the capability of supporting
those with Tonic only (rigid) seizures.
It is used by many professional care, respite and educational facilities
because of its highly adaptable operation.
It is equally perfect for domestic use where there are complex seizure patterns.
MED 12 Alert it Companion Epilepsy Detection Unit Includes P124A Cotton Sheet
– Enuresis / Incontinence Detection
– The sheet goes over the mattress and the controller plugs
into the HTM 6001 Pear push unit.
The Call unit in turn will activate an accessory call alert
when the mat comes in to contact with moisture.
The Cotton sheet can be washed at normal temperatures after
the connecting cables are disconnected.
MED 13. Enuresis Sheet Control Unit P163BBB With P145 And P141E Leads
– Enuresis / Incontinence Detection
– The sheet goes over the mattress and the controller plugs into the HTM 6001 Pear push unit
The Call unit in turn will activate an accessory call alert when the mat comes in to contact with moisture.
The Cotton sheet can be washed at normal temperatures after the connecting cables are disconnected.
(Medicare Hand unit not included.)
MED 14. Washable Cotton Enuresis Sheet Standard P142A
– For use with either MED 13 or MED 12.
MED 15. KYLIE Washable Cotton Enuresis Sheet Large P142E
– For use with either MED 13 or MED 12.
MED 22 PIR Movement Detector (Turn) Battery Operated
– The PIR movement sensor detects movement in the room and alerts
you if resident is moving around.
The device connects to the room call point unit via socket 1.
MED 23 PIR Movement Detector PSU
MED 24 Bed/Chair Weight Sensor
– Used with HTM 6001 Pear push unit plugged into socket 1
to activate an Accessory call combined with using a HTM 6022 Accessory Adaptor
(automatic monitoring unit)
The unit will learn that pressure is applied and then activate
an alarm when the pressure is released ideal with Beds and Chairs.
MED 25 Jelly Bean Switch
– Jelly Beans/Big Buttons – extremely sensitive switch Activates when tapped.
MED 26 Alert IT touch IT
MED 27 Finger Switch
MED 28 Radio PIR movement detector c/w power supply
MED 16 UPS (1200Mva)
AA GP GOLD Batteries Alkaline (each)
AA GP GOLD Batteries Rechargeable (each)
AA GP GOLD Batteries Rechargeable (each)
AAA GP GOLD Batteries (pack of 30)
– For HTM 6002 Pendants
½ AA 3.6v Lithium
– For Issue 2 and 3 HTM 4002 Pendants
½ AA 6.0v Lithium
– For early issue 1 HTM 4002 Pendants
CR2032 Coin Cell
PP3 9V for PIR units
Crocodile clips for ppl (pack of10)
Door contact keys
– For use with HTM 4004 door contacts issue 2 and 3
Pendant Lanyards
Mat Jack plug adaptor
Jack plug splitter